2.25 V Voltage Variable Absorptive Attenuator, 42 dB 1.8 - 2.5 GHz
Features
* * * * * * * * Single Positive Voltage Control, 0 to +2.25 Volts 42 dB Typical Attenuation Range at 2.4 GHz Low DC Power Consumption Lead-Free SOT-25 Package 100% Matte Tin Plating over Copper Halogen-Free "Green" Mold Compound 260C Reflow Compatible RoHS* Compliant Version of AT-119
MAAVSS0001 V3
Functional Schematic
5 VCC 4 VCTL
Description
M/A-COM's MAAVSS0001 is a GaAs MMIC voltage variable absorptive attenuator in a lead-free SOT-25 surface mount plastic package. M/A-COM fabricates the MAAVSS0001 with a proven monolithic GaAs 0.5 micron gate process that features full chip passivation for performance and reliability.
1 RF
2 GND
3 RF
Applications
The MAAVSS0001 is ideally suited for applications that require fine tuning, linear attenuation with voltage, and very low power consumption. Typical applications for the MAAVSS0001 include automatic gain control circuits in satellite radio receivers and other wireless receivers.
100pF
100pF
Pin Configuration
Pin
1 2 3 4
Function
RF GND RF VCTL VCC
Description
RF (input / output) Ground RF (input / output) Control Voltage DC Supply Voltage
Ordering Information1
Part Number
MAAVSS0001 MAAVSS0001TR-3000 MAAVSS0001SMB
Package
Bulk Packaging 3000 piece reel Sample Test Board (Includes 5 Samples)
5
Absolute Maximum Ratings 2,3
@ TA = +25C (unless otherwise specified)
Parameter
Input Power Supply Voltage VCC Control Voltage VCTL Operating Temperature Storage Temperature
Absolute Maximum
+21 dBm -1 V VCC +8 V -1 V VCTL VCC +0.5 V -40C to +85C -65C to +150C
1. Reference Application Note M513 for reel size information.
2. Exceeding any one or combination of these limits may cause permanent damage to this device. 3. M/A-COM does not recommend sustained operation near these survivability limits. * Restrictions on Hazardous Substances, European Union Directive 2002/95/EC. 1
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
RoHS Compliant
2.25 V Voltage Variable Absorptive Attenuator, 42 dB 1.8 - 2.5 GHz MAAVSS0001 V3
Electrical Specifications: TA = 25C, Frequency = 2.4 GHz, VCC = 3.3 V, Z0 = 50
Parameter
Insertion Loss Maximum Attenuation Attenuation Slope Return Loss
Test Conditions 4,5
VCTL = 2.25 V VCTL = 0.5 V 0.75 V < VCTL < 1.75 V 0.0 V < VCTL < 0.75 V 0.75 V < VCTL < 1.75 V 1.75 V < VCTL < 2.25 V 0.75 V < VCTL < 2.25 V 0.75 V < VCTL < 2.25 V 50% VCTL to 10% / 90% RF VCTL = 3 V, In-Band
Units
dB dB dB/V dB dB dB dBm dBm nS mV
Min.
-- 37 24 -- -- -- -- -- -- --
Typ.
2.4 42 -- 6 10 14 10 15 100 10
Max.
3.2 -- -- -- -- -- -- -- -- --
Input Power for 1dB Change in Attenuation Input 3rd Order Intercept Point Switching Speed Transients
4. External DC blocking capacitors are required on all RF ports. 5. VCC = +3.3 V @ 50 A typical. VCTL = 0 V to +2.25 V @ 50 A typical.
Application Schematic
VCC VCTL
Handling Procedures
Please observe the following precautions to avoid damage:
100 pF
RF IN/ OUT
Static Sensitivity
220 pF
100 pF
RF IN/ OUT
Gallium Arsenide Integrated Circuits are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity. Proper ESD control techniques should be used when handling these devices.
15 pF
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
RoHS Compliant
2.25 V Voltage Variable Absorptive Attenuator, 42 dB 1.8 - 2.5 GHz
Typical Performance Curves
Insertion Loss vs. Frequency @ 2.25 V Control Voltage
4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0.5 1.0 1.5 2.0 2.5 3.0 +25C -40C +85C 40 1.8 GHz 2.1 GHz 2.4 GHz 20
MAAVSS0001 V3
Attenuation vs. Control Voltage @ +25C
0
10
30
50
60 3.0 2.5 2.0 1.5 1.0 0.5 0.0
Frequency (GHz)
Control Voltage (Volts)
Typical Device Variation, 2.4 GHz
0
Attenuation vs. Frequency @ 0.0 V Control Voltage
0
10
10
20
20
30
30
40
40
50
50
+25C -40C +85C
60 3.0 2.5 2.0 1.5 1.0 0.5 0.0
60 0.5 1.0 1.5 2.0 2.5 3.0
Control Voltage (Volts)
Frequency (GHz)
Return Loss vs. Control Voltage
0
Insertion Loss Delta Normalized to +25C (-40C)
8 6 4
-5
-10
2
-15
0 -2
-20
1.8 GHz 2.1 GHz 2.4 GHz
-4 -6 -8
-25
1.8 GHz 2.1 GHz 2.4 Ghz
-30 2.0 1.5 1.0 0.5 0.0
3.0
2.5
2.0
1.5
1.0
0.5
0.0
Control Voltage (Volts)
Control Voltage (Volts)
3
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
RoHS Compliant
2.25 V Voltage Variable Absorptive Attenuator, 42 dB 1.8 - 2.5 GHz
Typical Performance Curves
Insertion Loss Delta Normalized to +25C (+85C)
8 6 4 2 0 -2 -4 -6 -8 3.0 2.5 2.0 1.5 1.0 0.5 0.0 1.8 GHz 2.1 GHz 2.4 GHz
MAAVSS0001 V3
Input IP3 vs. Control Voltage @ +25C
40 35 30 25 20 15 10 5 0 3.0 2.5 2.0 1.5 1.0 0.5 0.0
Control Voltage (Volts)
Control Voltage (Volts)
Input Power for 1 dB Change in Attenuation
30
Input IP3 vs. Control Voltage over Temperature
40 35 30
IIP3 @ +25C IIP3 @ +85C IIP3 @ -40C
25
20
25 20 15 10
15
10
5
1.8 GHz 2.4 GHz
5 0 3.0
0 3.0 2.5 2.0 1.5 1.0 0.5 0.0
2.5
2.0
1.5
1.0
0.5
0.0
Control Voltage (Volts)
Control Voltage (V)
Lead-Free SOT-25
Reference Application Note M538 for lead-free solder reflow recommendations.
4
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.


▲Up To Search▲   

 
Price & Availability of MAAVSS0001

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X